Place of Origin: | Guangzhou, China |
Brand Name: | HISEER |
Certification: | CE EN14511 |
Model Number: | AW12/B-QNNNE |
Highlight: | air cooled heat pump |
---|
Efficient galvanized cabinet air cooled heat exchangers for your home
AW12/B-QNNNE, single phase, heating & cooling unit, galvanized cabinet, R410a air source heat pump.
Air-source heat pumps, often used in moderate climates, use the difference between outdoor air temperatures and indoor air temperatures to cool and heat your home, as well as to supply domestic hot water.
HISEER AW12/B-QNNNE, designed and tested by EN14511, approved by TUV china branch, adopts the following world famous parts:
* Daikin scroll compressor
* Siemens controller
* SWEP or GEA plate type heat exchanger
* Schneider A/C contactor
* Emersion thermal expansion valve
* Emersion dry filter
*Soft start is standard part
ASHPs supply more energy than they consume. By extracting heat from the surrounding air, the heat energy released can be up to 4 times the energy required to power the equipment.
An ASHP system consists of a compressor and a carefully matched evaporator coil and heat exchanger. A refrigerant liquid which circulates within the system has a boiling point as low as minus 40˚C and evaporates when absorbing heat from the outside air. It is possible to extract considerable heat from the air at temperatures as low as minus 15˚C. The resulting refrigerant gas is then compressed adding more heat energy and raising its temperature to around 75˚C. This heat is then passed via the heat exchanger into water and used to provide space heating through radiators as for conventional heating systems, or via underfloor heating systems.
AW12/B-QNNNE
AIR TO WATER HEAT PUMP |
AW12/B-QNNNE |
|
Heat output/Power consumption at 7/35℃ |
kW |
13.0/3.6 |
Heat output/Power consumption at 7/45℃ |
kW |
12.5/4.2 |
Heat output/Power consumption at 7/55℃ |
kW |
12.2/5.3 |
Heat output/Power consumption at 2/35℃ |
kW |
11.1/3.5 |
Heat output/Power consumption at 2/45℃ |
kW |
10.8/4.2 |
Heat output/Power consumption at -7/35℃ |
kW |
8.0/3.5 |
Heat output/Power consumption at -7/45℃ |
kW |
7.9/4.2 |
Cool output/Power consumption at 35/7℃ |
KW |
11.5/4.3 |
Starting current |
A |
36 |
Soft-start relay |
|
Included as standard |
Power |
|
220-240V/1PH/50Hz |
Compressor |
|
DAIKIN Scroll |
Condenser |
|
Brazed plate heat exchanger |
Nominal flow heating medium |
l/s |
0.62 |
Internal pressure drop at nominal flow |
kPa |
20 |
Air flow |
m3/h |
5000 |
Nominal output fan |
W |
300 |
Max outgoing heating medium temperature |
℃ |
55℃ |
Dimensions(HxWxD) |
mm |
1075x1105x505 |
Pipe connector |
|
DN25 |
Weight |
kg |
175 |
The above data is tested by EN14511 |
Contact Person: Ms. Hu
Tel: 1393380568
Fax: 86-755-3987544
Industrial Grade Mixed refrigerant Retrofited refrigerant for R22
Mixed refrigerant / Retrofited refrigerant for R22 and R502
Mixed Refrigerant R404A (HFC-404A) Recyclable cylinder 400L / 800L / 926L
Economical R134 replacement (HCFC) r22 refrigerant cylinder / chlorodifluoromethane r22
R22 Refillable cylinder Odorless 1000L CHCLF2 R22 Refrigerant Replacement
R22 Replacement Chlorodifluoromethane (HCFC-22) home air conditioner refrigerant gas
R134a Pure gas cooling agent R134a refrigerant 30 lb Air Conditioning and Heat Pumps
Car automotive air conditioning r 134a refrigerant 30 lb, High Purity 99.90%
HFC R134a Auto air conditioning CH2FCF3 R134a Refrigerant 30lbs for commercial, industrial