Place of Origin: | China |
Brand Name: | Haodi |
Certification: | ISO |
Minimum Order Quantity: | Negotiation |
---|---|
Price: | Negotiation |
Packaging Details: | According to customer’s requirment |
Delivery Time: | 7-15days |
Payment Terms: | L/C,T/T,Paypal |
Supply Ability: | 20000 Tons/week |
Highlight: | refrigerant replacement |
---|
Mixed Refrigerant R409A replacement for CFC-12 for refrigerators, systems using R-12
An interim replacement for CFC-12 in refrigeration systems. Low- and medium-temperature retrofits.
Retrofit:R-409A is the recommended retrofit for R-12 and R-500 stationary DX systems, where an oil change to POE is not practical. R-409A is not recommended for use in automotive air conditioning system, or systems that utilize a flooded evaporator (i.e. centrifugal chillers). For these systems, R-134a is the recommended retrofit product.
Retrofitting Procedures
1. Establish baseline performance. Note the oil type in use and any system operating data (if system is operating properly). Check for existing leaks and identify any needed repairs.
2. Recover the existing refrigerant charge (DO NOT vent to atmosphere). Weigh the amount of refrigerant removed.
3. Perform any repairs identified in step 1 and fix any leaks.
4. Replace the filter-drier, and if necessary, elastomeric seals (O-rings. sight glasses. etc.). Verify the condition of the system oil; replace if necessary.
5. Oil changes are typically not required for R-409A. For low temperature mineral oil based systems, a partial (greater than 30%) oil change to AB is recommended.
6. Evacuate the system (less than 500 microns) and ensure it maintains a vacuum. If vacuum is lost, it may indicate that leaks are present in the system.
7. Charge system with R-409A refrigerant. Remove refrigerant as liquid only from cylinder. The initial charge amount should be approximately 85 – 90% of the standard charge for R-12 for TXV systems, and 80% for cap tube systems.
8. Adjust TXV set point and/or refrigerant charge to achieve the desired superheat. Low side pressure control settings may also need to be adjusted.
9. Monitor oil levels in the compressor. If necessary, adjust oil amounts to attain normal operating level (mid sight glass).
10. Label system clearly, indicating the type and amounts of system refrigerant and oil.
Specifications:
Property of chloride : |
|
Quality standard : |
|
Applications:Applications include many medium temperature refrigeration systems, vending machines, refrigerators, positive displacement chillers, humidifiers, and other systems using R-12 or R-500.
Competitive Advantage:
1.R409a of all specifications
2.OEM is accepted
3.Purity99.8%
4.Certifications of
SGS/ROSH/PONY/ISO9001/ISO14001/ISO16949
Contact Person: Ms. Hu
Tel: 1393380568
Fax: 86-755-3987544
Industrial Grade Mixed refrigerant Retrofited refrigerant for R22
Mixed refrigerant / Retrofited refrigerant for R22 and R502
Mixed Refrigerant R404A (HFC-404A) Recyclable cylinder 400L / 800L / 926L
Economical R134 replacement (HCFC) r22 refrigerant cylinder / chlorodifluoromethane r22
R22 Refillable cylinder Odorless 1000L CHCLF2 R22 Refrigerant Replacement
R22 Replacement Chlorodifluoromethane (HCFC-22) home air conditioner refrigerant gas
R134a Pure gas cooling agent R134a refrigerant 30 lb Air Conditioning and Heat Pumps
Car automotive air conditioning r 134a refrigerant 30 lb, High Purity 99.90%
HFC R134a Auto air conditioning CH2FCF3 R134a Refrigerant 30lbs for commercial, industrial