4F, Building 1, Huaming Ind. Park, Longhua New District, Shenzhen, Guangdong, China
Home ProductsAir Compressor Heat Exchanger

R407C Screw Air Cooled Heat Recovery Unit With Spiral Axial Fan 85 - 470 Tons

R407C Screw Air Cooled Heat Recovery Unit With Spiral Axial Fan 85 - 470 Tons

  • R407C Screw Air Cooled Heat Recovery Unit With Spiral Axial Fan 85 - 470 Tons
  • R407C Screw Air Cooled Heat Recovery Unit With Spiral Axial Fan 85 - 470 Tons
R407C Screw Air Cooled Heat Recovery Unit With Spiral Axial Fan 85 - 470 Tons
Product Details:
Place of Origin: China
Brand Name: EuroKlimat
Certification: ISO9001, ISO14001, OHSAS18001, CRAA, CQC
Model Number: EKAS
Payment & Shipping Terms:
Minimum Order Quantity: 1 pcs
Price: Negotiation
Packaging Details: Plywood
Delivery Time: 10 working days after received your payment
Payment Terms: T/T or L/C
Supply Ability: 500pcs per month
Contact Now
Detailed Product Description
Product Name: R407C Screw Type Air Cooled (heat Pump) Partial Heat Recovery Unit 85 - 470 Tons Capacity(ton): 85-470
Max Outgoing Water Temp.( °C): 55 Refrigerant: R407C
Startup Type: Y-Δ Power Supply: 380V/3~/50Hz
High Light:

waste heat recovery unit

,

heat recovery ventilation units

 

 

R407C Screw type air cooled (heat pump) partial heat recovery unit 85 - 470 tons

 

 

Specifications

 

 

Model  

EKAS

085

EKAS

095

EKAS

115

EKAS

125

EKAS

140

EKAS

150

EKAS

165

EKAS

180

Nominal cooling capacity kW 284.1 328.3 388.0 410.3 473.7 509.4 557.3 601.0
USRT 80.8 93.3 110.3 116.7 134.7 144.8 158.5 170.9
×104kcal/h 24.4 28.2 33.4 35.3 40.7 43.8 47.9 51.7
Nominal heating capacity* kW 322.7 354.7 426.9 431.3 491.6 528.6 578.4 623.7
USRT 91.8 100.9 121.4 122.6 139.8 150.3 164.4 177.3
×104kcal/h 27.8 30.5 36.7 37.1 42.3 45.5 49.7 53.6
Partial heat recovery capacity kW 71.0 82.1 97.0 102.6 118.4 127.3 139.3 150.2
×104kcal/h 6.1 7.1 8.3 8.8 10.2 11.0 12.0 12.9
Cooling compressor power kW 93.1 101.3 123.9 128.6 146.1 157.0 171.4 182.0
Heating compressor power kW 95.8 104.1 124.1 135.1 153.4 164.8 179.9 189.6
Capacity modulation   25% ~ 100% stepless modulation
Startup type   Y-Δ
Power supply   380V/3~/50Hz
Refrigerant Type   R407C
Circuit Qty.   1 1 1 1 1 1 1 1
Control mode   Electronic expansion valve
Compressor Type   Semi-closed double screw type
Qty.   1 1 1 1 1 1 1 1
Lubricant Code   EK02
Filling quantity   13x1 13x1 13x1 13x1 19x1 19x1 23x1 23x1
Fan Type   Spiral axial fan
Qty. No. 6 8 8 8 10 10 12 12
Capacity kW 10.8 14.4 14.4 14.4 18.0 18.0 21.6 21.6
Air flow ×104m3/h 12 16 16 16 20 20 24 24
Air side heat exchanger Type   Fins
Density piece/inch 16FPI
Water side heat exchanger Type   Dry shell-tube type
Water flow for cooling m3/h 48.9 56.5 66.7 70.6 81.5 87.6 95.9 103.4
Pressure drop of cooling water kPa 58 62 73 64 66 61 51 56
Water flow for heating* m3/h 55.5 61.0 73.4 74.2 84.6 90.9 99.5 107.3
Pipe diameter inch 4 5 5 5 5 8 8 8
Heat exchanger at the heat
recovery side
Type   Plate heat exchanger
Water flow m3/h 12.2 14.1 16.7 17.6 20.4 21.9 24.0 25.8
Pipe diameter inch 2 2 2 2 2 2 2 2
Rated current A 185 207 246 254 292 311 344 362
Startup current A 250 278 326 338 388 413 455 480
Max. startup current A 357 357 478 478 660 660 749 749
Dimensions Length mm 3200 4100 4100 4100 5000 5000 5900 5900
Width mm 2260 2260 2260 2260 2260 2260 2260 2260
Height mm 2525 2525 2525 2525 2525 2525 2525 2525
Weight of a single indoor unit Shipment of cooling only units kg 3865 4015 4165 4765 4810 4810 5380 5500
Operation of cooling only units kg 4015 4165 4315 4915 4966 4966 5540 5660
Shipment of heat pump units kg 3950 4100 4250 4850 4900 4900 5480 5600
Operation of heat pump units kg 4100 4250 4400 5000 5056 5056 5640 5760

 

 

Model  

EKAS

190

EKAS

200

EKAS

210

EKAS

225

EKAS

235

EKAS

250

EKAS

275

EKAS

300

Nominal cooling capacity kW 636.4 683.3 728.2 797.2 819.9 820.6 919.7 1018.7
USRT 181.0 194.3 207.1 226.7 233.1 233.3 261.5 289.7
×104kcal/h 54.7 58.8 62.6 68.6 70.5 70.6 79.1 87.6
Nominal heating capacity* kW 660.5 709.1 749.9 813.3 838.6 862.7 959.9 1057.2
USRT 187.8 201.6 213.2 231.2 238.4 245.3 272.9 300.6
×104kcal/h 56.8 61.0 64.5 69.9 72.1 74.2 82.6 90.9
Partial heat recovery capacity kW 159.1 170.8 182.1 199.3 205.0 205.2 229.9 254.7
×104kcal/h 13.7 14.7 15.7 17.1 17.6 17.6 19.8 21.9
Cooling compressor power kW 192.8 206.9 207.8 221.3 227.4 257.2 285.6 314.1
Heating compressor power kW 200.8 215.1 214.2 226.6 232.4 270.2 299.9 329.6
Capacity modulation   25% ~ 100% stepless modulation 12.5%~100% stepless modulation
Startup type   Y-Δ
Power supply   380V/3~/50Hz
Refrigerant Type   R407C
Circuit Qty.   1 1 1 1 1 2 2 2
Control mode   Electronic expansion valve
Compressor Type   Semi-closed double screw type
Qty.   1 1 1 1 1 2 2 2
Lubricant Code   EK02
Filling quantity   23x1 23x1 23x1 23x1 23x1 13x2 19+13 19x2
Fan Type   Spiral axial fan
Qty. No. 12 14 14 16 16 16 18 20
Capacity kW 21.6 25.2 25.2 28.8 28.8 28.8 32.4 36.0
Air flow ×104m3/h 24 28 28 32 32 32 36 40
Air side heat exchanger Type   Fins
Density piece/inch 16FPI
Water side heat exchanger Type   Dry shell-tube type
Water flow for cooling m3/h 109.5 117.5 125.3 137.1 141.0 141.2 158.2 175.2
Pressure drop of cooling water kPa 43 51 56 73 44 45 53 64
Water flow for heating* m3/h 113.6 122.0 129.0 139.9 144.2 148.4 165.1 181.8
Pipe diameter inch 8 8 8 8 8 8 8 8
Heat exchanger at the heat
recovery side
Type   Plate heat exchanger
Water flow m3/h 27.4 29.4 31.3 34.3 35.3 35.3 39.5 43.8
Pipe diameter inch 2 2 2 2 2 2 2 2
Rated current A 381 413 415 446 457 508 565 622
Startup current A 505 548 549 590 594 676 751 826
Max. startup current A 882 882 882 882 882 732 931 931
Dimensions Length mm 5900 6800 6800 7700 7700 8100 9000 9900
Width mm 2260 2260 2260 2260 2260 2260 2260 2260
Height mm 2525 2525 2525 2525 2525 2525 2525 2525
Weight of a single indoor unit Shipment of cooling only units kg 5520 5555 5755 5805 5835 9580 9675 9670
Operation of cooling only units kg 5680 5715 5935 5985 6015 9880 9987 9982
Shipment of heat pump units kg 5620 5670 5870 5920 5950 9750 9850 9850
Operation of heat pump units kg 5780 5830 6050 6100 6130 10050 10162 10162

 

 

Model   EKAS330 EKAS360 EKAS380 EKAS400 EKAS420 EKAS445 EKAS470
Nominal cooling capacity kW 1110.3 1201.9 1284.3 1366.6 1456.4 1548.1 1639.7
USRT 315.7 341.7 365.2 388.6 414.1 440.2 466.2
×104kcal/h 95.5 103.4 110.4 117.5 125.3 133.1 141.0
Nominal heating capacity* kW 1152.2 1247.3 1332.7 1418.2 1499.8 1588.5 1677.3
USRT 327.6 354.6 378.9 403.2 426.4 451.7 476.9
×104kcal/h 99.1 107.3 114.6 122.0 129.0 136.6 144.2
Partial heat recovery capacity kW 277.6 300.5 321.1 341.6 364.1 387.0 409.9
×104kcal/h 23.9 25.8 27.6 29.4 31.3 33.3 35.3
Cooling compressor power kW 339.0 364.0 388.9 413.8 415.6 435.2 454.8
Heating compressor power kW 354.4 379.2 404.7 430.3 428.4 446.6 464.9
Capacity modulation   12.5%~100% stepless modulation
Startup type   Y-Δ
Power supply   380V/3~/50Hz
Refrigerant Type   R407C
Circuit Qty.   2 2 2 2 2 2 2
Control mode   Electronic expansion valve
Compressor Type   Semi-closed double screw type
Qty.   2 2 2 2 2 2 2
Lubricant Code   EK02
Filling quantity   23x2 23x2 23x2 23x2 23x2 23x2 23x2
Fan Type   Spiral axial fan
Qty. No. 22 24 26 28 28 30 32
Capacity kW 39.6 43.2 46.8 50.4 50.4 54.0 57.6
Air flow ×104m3/h 44 48 52 56 56 60 64
Air side heat exchanger Type   Fins
Density piece/inch 16FPI
Water side heat exchanger Type   Dry shell-tube type
Water flow for cooling m3/h 191.0 206.7 220.9 235.1 250.5 266.3 282.0
Pressure drop of cooling water kPa 47 54 64 75 84 48 54
Water flow for heating* m3/h 198.2 214.5 229.2 243.9 258.0 273.2 288.5
Pipe diameter inch 8 8 8 8 8 8 8
Heat exchanger at the heat
recovery side
Type   Plate heat exchanger
Water flow m3/h 47.7 51.7 55.2 58.8 62.6 66.6 70.5
Pipe diameter inch 2 2 2 2 2 2 2
Rated current A 673 724 775 826 829 871 913
Startup current A 893 960 1028 1096 1098 1153 1188
Max. startup current A 1063 1063 1215 1239 1241 1241 1275
Dimensions Length mm 10800 11700 12600 13500 13500 14400 15300
Width mm 2260 2260 2260 2260 2260 2260 2260
Height mm 2525 2525 2525 2525 2525 2525 2525
Weight of a single indoor unit Shipment of cooling only units kg 10820 11060 11075 11160 11560 11660 11720
Operation of cooling only units kg 11140 11380 11395 11480 11920 12020 12080
Shipment of heat pump units kg 11010 11250 11290 11390 11790 11890 11950
Operation of heat pump units kg 11330 11570 11610 11710 12150 12250 12310

 

Note:
■ Rated cooling work conditions: outdoor dry bulb: 35°C; outlet water temperature: 7°C; water flow 0.172m3/(h·kW).
■ Rated heating work conditions: outdoor dry/wet bulb: 7°C/6°C; outlet water temperature: 45°C; water flow 0.172m3/(h·kW).
■ Rated working conditions for partial heat recovery units: inlet/outlet hot water temperature 50°C/55°C; inlet/outlet temperature of chilled
water: 12°C/7°C; ambient dry bulb temperature 35°C.
■ *Heating parameters marked with only apply to heat pumps units. Cooling only EKAS units do not have these parameters.
■ For on-site electric wiring, see the name plate or installation menu of the unit.

 

Inheriting the supreme air cooling design from EK Italy and equipped with the leading-edge total heat recovery technology, environment friendly units of R407C series can provide hot water with a temperature as high as 65°C to meet the air conditioning and hot water requirements of hospitals, clubs, factories, and so on.

 

More Energy Saving

 

The heat recovery technology improves cooling efficiency, reduces power consumption, and extends the service life of a unit. The total heat recovery technology recovers all condensate heat, saves power consumed by the fan of the heat exchanger at the air side, and reduces energy consumption by more than 15%.

 

One Unit for Three Purposes

 

One unit can be used for three purposes: cooling, heating, and free hot water. The unit can provide hot water with a temperature up to 65°C to meet guest house showering, kitchen cleaning, and factory hot water consumption requirements, thus saving investment in hot water equipment.

 

Less CO2 and More Environment Friendly

 

EK air conditioners feature a leading-edge total heat recovery technology to use waste heat, greatly save energy, and effectively mitigate the heat island effect in cities due to waste heat dissipation.

 

Easy Installation

 

The unit can be easily installed outside and requires no dedicated equipment room or operator. Free hot water is available as long as you connect the hot water pipes.

Contact Details
Shenzhen SAE Automotive Equipment Co.,Ltd

Contact Person: Ms. Hu

Tel: 1393380568

Fax: 86-755-3987544

Send your inquiry directly to us (0 / 3000)