R408a SGS / ROSH Passed 99.8% Purity r408a refrigerant / mixing / blend refrigerants

R408a SGS / ROSH Passed 99.8% Purity r408a refrigerant / mixing / blend refrigerants

  • R408a SGS / ROSH Passed 99.8% Purity r408a refrigerant / mixing / blend refrigerants
  • R408a SGS / ROSH Passed 99.8% Purity r408a refrigerant / mixing / blend refrigerants
R408a SGS / ROSH Passed 99.8% Purity r408a refrigerant / mixing / blend refrigerants
Product Details:
Place of Origin: China
Brand Name: Haodi
Certification: ISO
Payment & Shipping Terms:
Minimum Order Quantity: Negotiation
Price: Negotiation
Packaging Details: According to customer’s requirment
Delivery Time: 7-15days
Payment Terms: L/C,T/T,Paypal
Supply Ability: 20000 Tons/week
Contact Now
Detailed Product Description
High Light:

refrigerant replacement

,

refrigeration gas

R408a SGS / ROSH Passed 99.8% Purity r408a refrigerant / mixing / blend refrigerantsR408a SGS / ROSH Passed 99.8% Purity r408a refrigerant / mixing / blend refrigerants 0

Retrofit:System components (TXVs, line sizes, compressors) offer similar performance with R-502 and R-408A and usually do not requre changing when retrofitting.
Retrofit Procedure
1. Establish baseline performance. Note the oil type in use and any system operating data (if system is operating properly). Check for existing leaks and identify any needed repairs.
2. Recover the existing refrigerant charge (DO NOT vent to atmosphere). Weigh the amount of refrigerant removed.
3. Perform any repairs identified in step 1 and fix any leaks.
4. Replace the filter-drier and, if necessary, elastomeric seals (O-rings, sight glasses, etc.). Verify the condition of the system oil; replace if necessary.
5. Evacuate the system (less than 500 microns) and ensure it maintains a vacuum. If vacuum is lost, it may indicate that leaks are present in the system.
6. Charge system with R-408A refrigerant. Remove refrigerant as liquid only from cylinder. The charge ratio should be approximately 85-90% of the charge weight for R-502.
7. Adjust TXV set-point and/or refrigerant charge to achieve the desired superheat.
8. Monitor oil level in the compressor. If necessary, adjust oil amount to attain normal operating level (mid-sight glass).
9. Label system clearly, indicating the type and amounts of system refrigerant and oil.

R408a SGS / ROSH Passed 99.8% Purity r408a refrigerant / mixing / blend refrigerants 1

Specifications:

Property of chloride :

Molecular Weight

87.01

Boiling Point, °C

-44.4

Critical Temperature, °C

83.8

Critical Pressure, Mpa

4.42

Specific Heat of Liquid, 30°C, [KJ/(kg°C)]

0.36

ODP

0.016

GWP

0.652

 

 

 

Quality standard :

Purity, %

≥99.8

Moisture, PPm

≤10

Acidity, PPm

≤1

Vapor Residue, PPm

≤100

Appearance

Colorless, clear

Odor

Odorless

 

 

Applications:R-408A is a retrofit solution for medium and low temperature refrigeration systems that are currently using R-502. R-408A should not be mixed with R-502 or used to top off the charge of an existing system operating on R-502.

 

Competitive Advantage:

1.R408a Refrigerant of all specifications
2.OEM is accepted
3.Purity 99.8%
4.SGS/ROSH/PONY/ISO9001/ISO14001/ISO16949

Contact Details
Shenzhen SAE Automotive Equipment Co.,Ltd

Contact Person: Ms. Hu

Tel: 1393380568

Fax: 86-755-3987544

Send your inquiry directly to us (0 / 3000)

Other Products