4F, Building 1, Huaming Ind. Park, Longhua New District, Shenzhen, Guangdong, China
Home ProductsAir Conditioning Recovery Machine

Coal Mine 5000 Guass SUS 304 Magnetic Water Descaler With Air Conditioning System

Coal Mine 5000 Guass SUS 304 Magnetic Water Descaler With Air Conditioning System

    • Coal Mine 5000 Guass SUS 304 Magnetic Water Descaler With Air Conditioning System
    • Coal Mine 5000 Guass SUS 304 Magnetic Water Descaler With Air Conditioning System
  • Coal Mine 5000 Guass SUS 304 Magnetic Water Descaler With Air Conditioning System

    Product Details:

    Place of Origin: China
    Brand Name: YLD
    Certification: CE/ SGS
    Model Number: YLC-3

    Payment & Shipping Terms:

    Minimum Order Quantity: 1 unit
    Price: negotiation
    Packaging Details: Packed with EPE, and then with plywood case for outer packing
    Delivery Time: 10 working days after received your payment
    Payment Terms: T/T or western Union or L/C
    Supply Ability: 500 units per month
    Contact Now
    Detailed Product Description
    Product Name: Magnetic Water Descaler Application: Coal Mine
    Inlet & Outlet Diameter: DN80 Flow Rate: 80m3/Hr
    Material: SUS 304/316/316L Connection Mode: Flange And Thread
    Working Temperature: 0~90 ℃ Magnetic Intensity: 5000 Gauss

    Coal Mine 5000 Guass SUS 304 Magnetic Water Descaler With Air Conditioning System          

     

              

     Product introduction
     
    1 sterilization, algae principle
    Since NdFeB magnetic water processor to generate a magnetic field in the turbulent waves, destroyed cell membrane ion channels, changing the cell to adapt to current and internal control environmental conditions necessary for survival, to the loss of viability and death. Meanwhile, after the magnetic excitation of water molecules dissolved oxygen in the water can surround blockade, destroyed the life of microorganisms required for the reaction of oxygen sources, so as to achieve a good sterilization, algae effect, to prevent the generation of biological sludge.
    (2) rust, corrosion principle
    Metal corrosion to oxygen, the action of high-frequency electromagnetic energy package single water molecule dissolved the oxygen molecules dissolved in water, the dissolved oxygen as an inert, corrosion of the metal required to seal off the source of oxygen. Meanwhile, high-frequency electromagnetic waves stirred up overhanging composite modulation frequency of the electromagnetic field generated by the "skin effect" in the wall gathered excess negative charge, while in the water gathered inside excess positive charge. Positive charge strongly repel the positively charged homosexual Fe3 +, blocking Fe3 + Fe loses electrons becomes separated from the metal wall into the water; while excess negative electrons on the wall also continue to attract the positively charged Fe3 +, hinder it is soluble in water; so that the original wall of the Fe2O3 (red rust) reduction of the force with strong corrosion-resistant black rust adventitia Fe2O4.
     
     
     Scope of application

     

    Plastics industry

    The buildup of sludge can be prevented in the cooling circuits of the machines and the tools. Cooling and heating systems equipped with our technology are largely maintenance free, thus assuring the highest productivity and availability and leading to lower overall production costs as well.

    Housing and real estate

    Can be used to cut down heating, cooling and maintenance expenses significantly. By using our chemical-free technology, layers and deposits in all HVAC and plumbing systems can be minimised with a lasting effect. This helps to protect the whole installation against damages and failures as well as against the efficiency losses that are the most common causes for increased consumption of energy and water over the course of the system’s life cycle. In old buildings, the gradual cleaning of the heat exchangers, valves and radiators typically translates into substantial energy savings thanks to the recovery and restoration of the system efficiency.

    Transport and traffic

    In shipping our technology is used e.g. for fresh-water supply to counteract limescale in pipes and the high maintenance costs resulting from it. A Scandinavian ice-breaker fleet, among others, has been using our technology for a long time with great success.

    Hotels and Restaurants

    The whole piping system of the drinking water and/or hot-water in hotels and restaurants supply together with all of its components and critical appliances can be protected against limescale deposits and rust with the help of the chemical-free water magnetic treatment. Being completely maintenance-free after the initial installation, the Bauer pipe jet device ensures cost-optimised operation while providing thorough and continuous protection against corrosion and potentially costly leakages and water damages. With a suitable filter system, the technology can also be used to protect the HVAC systems such as cooling and heating circuits. Additionally, the Bauer pipejet device looks after the efficiency of the system by keeping the heat exchangers and transfer surfaces as well as the water itself in pristine condition.

    Cooling Towers

    Air conditioning systems in shopping malls and office buildings are a must nowadays.

    With the help of an appropriate filtering system, maintains the water in the cooling circuits in crystal clear condition and the piping, heat exchangers and other equipment free of deposits and layers.

    Thanks to the layer-free surfaces in the equipment, a better performance of the complete system can be achieved with reduced need for maintenance and lower water and energy consumption.

    Agricultural irrigation

    In controlled large-scale field experiment it was found that magnetic treatment affects the quality of irrigation water. Treated water contributes to an increase in crop yield, both in quality and quantity.

    The level of return in individual farms depends on three key factors: the tyoe of equipment, the water quality, and the mode of operation of the apparatus.

    Agricultural use is not limited to farming alone but also can be implemented for golf courses, greenhouse irrigation and many other horticultural venues.

    Benefits: Increased root growth

              soil hold moisture longer

              water conservation equals less man hours

              less energy required to pump and irrigate

              increased fertilizer efficiency,less chemical cost

              de-scaling of piping

              unclogged water jets

              bigger crop yield


     

        FAQ:
     
                                      01. What is the capacity(m3/hour)you required for this equipment?

                                              or you could confirm diameter of the water pipe.

                                        02. What is the material for this descaling equipment?
                                               Ordinary carbon steel is Okay? stainless steel(SS304/SS316)?
                                               Which means,what is the source of raw water to be treated?
                                        03. What is the magnet power for it?
                                               ordinary 5000 gauss?or higher?

     


    Specifications: (The practical dimension could be customized )

    Model

                    Inlet and outlet

    Dimension(mm)

    Flow rate

    Vertical center

    Working medium

    weight

     

    mm

    inch

    diameter*length

    m3/h

    strong magnetism (mt)

    temperature (℃)

    Kg

    YLC-1

    25

    1

    108×330

    4.9

    160

    0-90

    10

    YLC-1.5

    40

    1.5

    108×330

    12

    160

    0-90

    20

    YLC-2

    50

    2

    159×450

    19

    160

    0-90

    30

    YLC-2.5

    65

    2.5

    159×450

    28

    160

    0-90

    40

    YLC-3

    80

    3

    159×450

    50

    160

    0-90

    45

    YLC-4

    100

    4

    219×560

    80

    160

    0-90

    50

    YLC-5

    125

    5

    219×600

    125

    160

    0-90

    60

    YLC-6

    150

    6

    273×740

    180

    160

    0-90

    70

    YLC-8

    200

    8

    325×790

    320

    160

    0-90

    90

    YLC-10

    250

    10

    377×850

    480

    160

    0-90

    110

    YLC-12

    300

    12

    426×800

    600

    160

    0-90

    130

    YLC-14

    350

    14

    478×950

    750

    160

    0-90

    160

    YLC-16

    400

    16

    530×1000

    850

    160

    0-90

    210

    YLC-18

    450

    18

    630×1050

    950

    160

    0-90

    260

    YLC-20

    500

    20

    720×1100

    1100

    160

    0-90

    330

     Coal Mine 5000 Guass SUS 304 Magnetic Water Descaler With Air Conditioning System
     

    Contact Details
    Shenzhen SAE Automotive Equipment Co.,Ltd

    Send your inquiry directly to us (0 / 3000)

    Other Products