♦ Customer service report printing with integrated printer.
♦ Leakage diagnosing and detecting in the refrigeration system.
♦ Refrigerant recycling ,vacuuming ,filling ,oil supply.
♦ Specific interface for small container of coolant supply.
♦ Large-screen menu in both of the Chinese and English language, and intelligent operator interface.
♦ Simple pipeline connection. Operation starts once the hose of the machine is connected to the interface of the air conditioner yet to be tested.
♦ High-precision electronic scale weighs the refrigerant filling and reclaiming.
♦ Its purification & filtration system efficiently ensures recovery of used refrigerant.
♦ It employs high-duty vacuum pump.
♦ It adopts unique automatic protection design to prevent liquid attack and ultra-high pressure explosion.
♦ Main components are originally imported to guarantee excellent performance.
Home Beauty Fractional Co2 Laser Machine For Smooth Burnt Scars / Wrinkle Removal
Specifications
Laser type | Carbon Dioxide Fractional Laser |
Laser wavelength | 10600nm |
Laser power | Up to 40W (optional) |
Light system | 7 joint arms |
Pulse duration | 100-5000ms |
Facula | Single mode |
Focussed diameter of the beam | 0.25mm |
Focal area | 0.05mm2 |
Output form | Ultra Pulase, fractional |
Scanning Mode | Sequence, random, parallel (switchable) |
Scanning shapes | Triangle/square/rectangle/round/oval/hexagon/linear |
Area of diagram | ≤20mm*20mm |
Interface colourful touch screen | 8.4 inch |
Refrigerating system | Air-cooling, water-cooling |
Input power | AC230V±10%, 50Hz/ AC 110V ± 10% 60Hz |
Work Mode | Intermittent loading |
Packaging Details: | aluminium box |
Delivery Detail: | 18 working days after payment |
Fractionated CO2 Laser Skin Resurfacing
Photos Courtesy of: Renato Rodríguez, MD
The signs of an aging face include lines, wrinkles, age spots and a downward drooping of facial features.
Although having surgery can help to correct the positioning of aging tissue, it cannot restore the skin's once youthful glow. For those patients with medium to deep wrinkling who wish to avoid surgical procedures but
desire a youthful, refreshed skin tone, Pixel® CO2 skin resurfacing is the ideal choice. Years ago, CO2 skin resurfacing fell out of favor due to the treatment's long downtimes and risk of complications. Now with the Pixel CO2, you again see the fabulous results only available with CO2 but with a considerable reduction in downtime.
In fact, with Pixel CO2, the average patient will only see about 3 to 5 days of minor downtime.
Best of all, you have two options to meet your fractional CO2 needs. If you currently own a CO2 system, Alma Lasers offers the Pixel® CO2 OMNIFIT handpiece, designed to fit nearly any standard CO2 resurfacing laser.
If you are new to CO2 resurfacing or looking for a complete system, Alma offers the Pixel CO2 system. This 30-watt, standalone unit gives you the convenience of two pixelated handpieces, a 7 X 7 and a 9 X 9 array, plus two surgical tips. Either Pixel CO2 solution will provide you the perfect tool to meet your patients' needs through Pixel Perfect laser skin resurfacing procedures.
With the Pixel CO2, laser light passes through the patented Pixel® micro optics lens array to penetrate the skin with tiny thermal channels. This creates an ablative and thermal effect in only these channels — a micro-injury — without disturbing the surrounding tissue. The tissue surrounding the micro-injury sites (about 15-20 percent of the treatment area) start the process of healing. The intact, undamaged skin around the treatment site is what promotes quicker healing for a faster recovery.
Advantage
1) Up to 5 fractional treatment modes, dermis and epidermis treatments are effective at the same time in
compositive mode;
2) Up to 200mj single-point energy;
3) 5 default graphics for precise scanning with up to 10 levels of scan coverage;
4) 3 kinds of scanning tips and 1 kind of cutting tip offered;
5) Unique DIY graphic scanning function for best match with any target shape;
6) 30w world's top RF CO2 laser installed (20w/10w for Optional);
7) More cleaning and smelless with initiative patented Off-gas Purification System installed;
8) High precise scanning with top quality scanning system;
9) Highly improved overall visual effect and stability adopted injection process production;
10) Convenient and easy-work handpiece suitable for body mechanics;
11) Advanced safety protection with real time online self-detection system;
12) Treatment safety and comfort improved with pixel energy respective setup.
What is CO2 Fractional Laser?
Fractional CO2 Laser is a new technology that corrects many dermatological and cosmetic skin conditions through one procedure. The procedure corrects conditions such as superficial lesions, scars, skin texture, wrinkles, As the laser scans the surface of the patient’s skin, it will create thousands of micro-thermal zones
in the treated areas which will promote the production of new collagen, resulting in healthier, smoother and younger-looking skin.
CO2 Fractional Laser Results
The results from a Fractional CO2 Laser will be visible after about one week, once the treated area of the
skin (little brown scabs) will peel off. For me, this took about one week. After that, I was able to see my new,
fresh skin underneath. Although seeing apparent differences after 1-2 weeks, the full results came about a
month after the procedure. My skin got a new healthy glow, the overall skin texture was improved, my pores
were diminished and some fine lines under the eyes decreased. Along with the above, the treatment also took years of sun damage off my face allowing me to go without makeup and look more youthful with an even skin
tone.
Application
1. Skin renewing and resurfacing
2. Wrinkle removal. skin tightening
3. Acne and scar removal , melasma removal
4. Smooth burnt scars and surgery scars. traumatic scars ,etc
5. Remove intractable chloasmas and pigmentation
6. Sun damage recovery
User Friendly Programmable Thermal Shock Test Chamber
Main features of Thermal test chamber:
1. Programmable Controller with RS232C, 7 LCD touch panel control
2. Stainess steel Interior, galvanized steel sheet exterior
3.2PCS stainless steel loading shelves free
4. Multipane viewing window with heater
5. 50mm diameter feed-through port
6. Floor stand with castors.
Main parts imported: Tecumseh, Danfoss, , siginomiya, ALCO, RANCO, etc.
Top-grade raw material insure the reliability performance
Excellent design bring you good user experiences
Brief introduction of User friendly Programmable Thermal Shock Test Chamber:
The equipment is mainly designed according to the national standard and user-defined requirements. It can simulate different environmental conditions, such as heat-endurance, cold-endurance, dryness-endurance, and humidity-endurance, which defines the performance of material. By testing the product under different environmental conditions to see whether its performance can meet the intended requirements. It is widely applied in the industries of electronics, electrical equipment, vehicle, metal, foodstuffs, chemistry, building materials, luggage, adhesion tape, printing, packaging, and other product components and materials
Application:
Thermal Shock Test Chamber is used to quickly find the hidden mechanical weaknesses in electronic components when test specimens are exposed to rapid thermal shock condition, and you will not only reduce the premature failures but also increase the reliability of your products when you choose our thermal shock test chamber.
1.3-zone design: High temperature zone, cold temperature zone, and testing zone.
2. The test specimens under test are stationary in the testing zone.
3. Touch-control operation interface for ease of use.
4. Max. 999H and max. 9999 cycles for high or low temperature shock for thermal shock test chamber.
5. Automatic cycling shock or/and manual selective shock are available
6. Water cooled, binary cooling system for quick cooling effect.
Knowledge of theemal shock chamber:
Thermal shock test is a method of environmental testing that subjects a product to alternating extremes of high and low temperatures. Thermal shock testing allows for the observation of changes in product characteristics and failure occurrence caused by different materials and their thermal expansion coefficients. A thermal gradient difference in the different parts of the object expands by different amounts and can cause cracking and failure. KOMEG brand thermal shock and thermal stress chambers have been designed to operate in accordance with reliability programs, quality control, and commercial test programs and military test.
KOMEG offers several configurations of thermal shock chambers capable of meeting a wide variety of testing needs.
Vertical, two zone chamber has hot and cold zones that can be controlled independently.
Horizontal, three zone thermal shock chamber utilizes controlled areas for hot, ambient and cold temperatures.
Double duty thermal shock chambers from KOMEG are designed with hot zones above and below the cold zone and a two compartment product carrier that simultaneously moves products between the hot and cold zones.
Warranty: One year free warranty for whole set machine, lifelong time maintainance.
After-sale service: Feedback within 2 hours after get the call.
Service: OEM service, Design service, Buyer lable service.
Your attention will be highly appreciated.
We supply 7*24 hours service.
Technical Parameters:
Model |
|
|||||||||||||||
72B | 100B | 150B | 200B | 252B | 300B | 480B | ||||||||||
Interior size | W(mm) | 450 | 500 | 600 | 670 | 700 | 800 | 800 | ||||||||
H(mm) | 400 | 450 | 500 | 600 | 600 | 600 | 800 | |||||||||
D(mm) | 400 | 450 | 500 | 500 | 600 | 650 | 750 | |||||||||
Exterior size | W(mm) | 1490 | 1540 | 1640 | 1720 | 1750 | 1850 | 1850 | ||||||||
H(mm) | 1790 | 1840 | 1890 | 2000 | 2000 | 2000 | 2200 | |||||||||
D(mm) | 1600 | 1700 | 1830 | 1850 | 1930 | 1980 | 2500 | |||||||||
Test weight(KG) | 5 | 10 | 12 | 15 | 18 | 20 | 20 | |||||||||
Low Temp. chamber | -70ºC~-10ºC | |||||||||||||||
Pre-cooling time | +20ºC~-70ºC ,Within 60 min | |||||||||||||||
Test. chamber | -55ºC~+150ºC | |||||||||||||||
High Temp. chamber | +60ºC~+200ºC | |||||||||||||||
Pre-heating time | +60ºC~+200ºC ,Within 20 min | |||||||||||||||
Recovery time | High-Temp Exposure 30 min | |||||||||||||||
Low-Temp Exposure 30 min | ||||||||||||||||
Recovery time within 5 min | ||||||||||||||||
Safety device | No fuse breaker, over pressureover heat and over current protection for compressor,over temperature protection, over load protection for blower, dry heat protection | |||||||||||||||
Standard accessory | Cable port(portΦ50mm)*1, shelves*2 | |||||||||||||||
Interior material | Stainless steel plate(SUS 304) | |||||||||||||||
Exterior material | Baked painting steel or stainless steel(SUS304) | |||||||||||||||
Insulation material | Rigid polyurethane Foam+glass fiber wool | |||||||||||||||
Refrigeration system | Water Cooled | |||||||||||||||
Semi-hermetic compressor, cascade refrigeration system, CFC free refrigerant(HFC-507 and HFC-23) | ||||||||||||||||
Controller | Panel:7-inch LCD Touch panel,Chinese or English display selectable | |||||||||||||||
Operation model:Program or fix point running | ||||||||||||||||
Memory capacity:120programs,1200steps,all repeat 999cycles,part repeat 99 cycles. | ||||||||||||||||
Accuracy:Temp.:0.1% of F.S±1 digit Humidity:0.1% of F.S±1 digit | ||||||||||||||||
Input:Temp.:pt-100 Humidity:pt-100 or ~5V DCV | ||||||||||||||||
Ambient Temp. | +5ºC~+35ºC | |||||||||||||||
Power | AC 380±10%50Hz ,3 phase 4 wires +Ground Wires | |||||||||||||||
Note:1. We reserve the right to change specifications without prior notice 2. Customized sizes and configurations available |
Stationary RF Skin Tightening Machine / RF Beauty Equipment With Micro - Needle Head
Functions:
Reduce the appearance of wrinkles, sagging skin, rough texture, fat, and cellulite.(4 changeable heads for different parts of body,face and eyes care)
•Wrinkle removal, skin lightening
•Skin lifting and tighten Elasticity enhancement
•skin smooth
•pore shrinking, calming down redness.
•Orange tissue removal
•remove stretch marks
•Improve pores
Dear user:
Thanks for using our company’s products,in order to fully make use of the products,we sincerely suggests follow:
This product does not belong to medical,please don’t use for disease treatment!
Parts Introduction
1.Touchscreen
2.Non-adjustable low speed handle
3.Adjustable low speed handle
4.Service brake
5.Power switch
6.Power supply line jack
Accessories
Any part of instrument made of PMMA material (for example:accessories shelf ,panel ,transparent handles, ,etc.). Do not use alcohol or corrosive solvent to wipe clean.
Basal Operation
1. First,insert the steadying bar into the frame hole,aim the hole in steadying bar at the hole in frame ,the fasten it with hex socket screws. Then put the accessories frame into the steadying bar.
2.Put the accessories well and connect them to host.
(1)Insert the Non-adjustable low speed handle into jask[2].
(2)Insert the adjustable low speed handle into jask[3]
(3)Put the brake service on the ground,Insert the brake service into jack[4].
3.Insert power supply line to [6],turn on the power switch [5],input default password “000000” to enter interface as shown in (Fig 1)
4.In interface as(Fig1) shows:
1.Click on “basic setting” to select Language,set Date and Time.
2.The “advanced setting” is only for manufacturer,Users do not use.
3.Click on”picture” to enter interface as (Fig 2)
4.Click on”” to return interface as (Fig 1)
Thermage Treatment
Non-adjustable Low speed handle
Suitable for thermage work head.Click on the “II” step on the service brake once,the thermage work head is only output once.
SRF Nursing process
1.Deep clean the treated skin.
2.Applied anesthetic in the nursing area,and to be anesthetic effect.
3.Apply cold gels on the treated skin.
4.In interfase as shown (Fig 2), click on “low speed SRF” to enter interface as (Fig 3) Thermage treatment function.
5.lnsert the Thermage work head into the Non-adjustable low speed handle.
6.Set working time. The system default work time is 30 minute,click on "<<" and ">>" of work time to regulate,the range is 1 to 120 minutes.
7.Select the work mode. The system default automatic mode is P4,click on "<<" and ">>" of automatic mode to regulate,the details is following:
Automatic mode:
M1 3000ms(long)
M22600ms
M32200ms
M41800ms
M51400ms
M61000ms(short)
Manual mode: 1000ms to 3500ms
8.Set RF output intensity. The system default RF intensity is 1,click on "<<" and ">>" of RF intensity to set,the range is 1(weak) to 8(strong)
9.Click on “PDT” select turn on/off light therapeutics.
10.Click”II”,the system begin to work,the beautician hold the non-adjustable low-speed handle cluing to the skin,Step on the service brake with foot once,then release,move the handle in adifferent part to continue operating.Beautician step on service brake each time,mean that the Thermage work head output engage once at same time.
11.When Thermage treatment is completed.we may use lce to cool the skin,it can relieve swelling,relieve pain effect.
12.Click on”” to return interface as(Fig 1).
Adjustable Low speed handle:
Suitable for MRF micro-needle work head. Adjustable means that the output length of MRF micro needle work head can be adjusted. Click on "11" ,step on service brake once,the micro-needles work head is only output once.
MRF Nursing process
1.Deep clean the treated skin.
2.Applied anesthetic in the nursing area,and to be anesthetic effect.
3.Apply effective products in the treated skin.
4.Click on “Low speed MRF” to enter interface as (Fig 4) MRF treatment function
5.Chooce appropriate micro-needle work head,in sert it into the adjustable Low-speed handle
6.Depending on treatment part,adjusting the length of the micro-needles(twisting yellow ring).
0.25,0.5 is suitable for eyes
1.0,1.5,2.0 is suitable for face
2.0.2.2,3.0 is suitable for bady
7.set working time
8.Select “Time of needles being out”.The system defaule is 300ms, click on "<<" and ">>" to adjust,the range is 250ms to 600ms.
250ms to 300ms is suitable for eyes
300ms to 450ms is suitable for face.
450ms to 600ms is suitable for body.
9. Select “Time difference of MRF and needles being out”,The system default is 2ms,click "<<"and ">>" to adjust, the range is 1ms(fast) to 10ms(slow).O-stands for MRF and needle output at same time.
10.Regulate “RF intensity”.The system default is 1,click on "<<"and ">>" to adjust,the range:1(weak)~10(strong).OFF stands for close MRF function.
11.Click on “PDT”,selest turn on/off light therapeutics
12.Click on “II”,the system begin to work,the beautician hold Adjustable low-speed handle cluing to slin.Step on service brake with foot once,then release,move the handle in a different part to continue operating.Beautician step on service brake each time,means that the MRF micro-needles work head output engage once at same time.
CAUTION:During face and body treated,when the length of MRF micro-needles work head arrive 2.0mm or above; MRF intensity arrive 8 or above; we recommended only operate one time in the same location.Do not repeat operating twice.
13,when MRF treatment is completed.we may use lce to cool the skin,it can relieve swelling,relieve pain effect.
SRF&MRF Cautions
1.When insert MRF micro-needles work head and Thermage work head to the handle,you must check and confirm whether fully inserted.
2.During the treating, the customer do not wear any metal ornaments
3.Must apply cold gel when use dot matrix SRF electrode head.
4.We recommended to tum off red led therapeutics when do eyes treated.
5.When gels or other cream products get into Thermage work head,high temperature is easy caused smoking ,please cleansing it immediately
Forbidden Group
1.People with heart disease or high blood pressure,,or configured cardiac pacemaker
2.Patients with acute inflammation,asthma,deep vein thrombosis,thyroncus,caner
3.People with hemorrhagic disease,trauma or who is bleeding.
4.Pregnant women
5.Medical Plastic parts,or parts with artificial in filling inside
6.People with metal inside the body(include metallic tooth)
7.Patient with skin inflammation or with edema
8.People with an abnormal immune system
9.Numb or insensitive to heat
Touch Screen Calibration
1.Turn on the Power switch.click on any place of the touch screen when in waiting interface state to enter calibrating program.
2.Follow the prompts in accordance with the left-top,right-top,right-bottom,left-bottom and center to click on the screen prompts symbol”+”
3.Calibration is finished, ,the system enter to waiting interface
4.Turn off the Power switch ,reboot the system.
Technical Parameters
Input Voltage: AC 220V/150Hz AC 110V/60Hz
Output Power:55VA
LED: Red 650nm/5mWX1
Packing List
1,Host 1SET
2,Adjustable Low-speed handle 1PCS
3,Non-adjustable Low-speed handle 1PCS
4,MRF micri-needles work head(25needles) 2PCS
5,MRF micro-needles work head(49needles) 2PCS
6,MRF micro-needles work head(81needles) 2PCS
7,Thermage work head 2PCS
8,Service brake 1PCS
9,Power supply line 1PCS
10,User manual 1 COPY
11,Hex socket screw 1PCS
12,Hex socket wrench 1PC
13,Accessories frame 1PC
Symbols and Meanings
Warning Symbol |
Meaning |
Danger |
If used incorrectly will bring the risk of death or serious injury! |
Waning |
If used incorrectly will cause possibility ill of death or serious injury! |
Attention |
If used incorrectly will cause personnel injury or damage to the goods! |
Danger |
Device exists high pressure risk of high voltage output terminals! |
Waning |
If used incorrectly will cause personnel injury! |
*Things damage refers to housing,property,livestock and pet damage
Contraindications
1.The following symptoms were forbidden to use
(1)Patients who used by Heart rate regulator,cardiac pacemaker,ECS;
(2)The use of artificial bone; Patients with silicosis
(3)Drunkor high fever patients
(4)Patients with higher sensiticity mental Disease and wpilepsy patients
(5)Patients with no independent expression consciousness and can not take care of the themselves.
(6)Patients with metal materials in body(including metal teeth),pregnant women,cachexia,malignant tumor.
(7)Severe hypertension and severe patients with cardiovascular and cerebrovascular disease.
(8)Patients with renal failure.
(9)Patients with severe infection
2.The following please use under the guidance of professionale
1.Women during menstruation
2. Children
3.Hemorrhagic disease or teauma,inflammation skin disease,skin infection
4.Patients with feeling numb,no response to cold and heat;
5.The immune system has defects,scar formation history,physical disease;
6.The people who has taken face-lifting or her body has artificial thing
Attention
1.First check the host, accessories ,power supply line is broken or not before use.
2.Start system,in addition to television,refrigerator,Do not turn on electrical power device at same time.
3.Before use,pleace take the hearing aid,electronic wrisrwatch, magnetic, card,mobile phone and other things off first.Pay attention to the child’s care to avoid touching.
4.During the using process,drink more water based on your physical.
5.In case of happen specila circumstances or accident,pleace immediately stop using and consult professionals.
6.Patients with following medical electrical device cannot use this system at the same time
----- Patients who implantable cardiac pacemaker,heart rate regulator,other electronic devices
----- Artificial heart lung device and other device to sustain life
----- Patients with ECG scanner device
----- Patients with metal materials in body (including metal teeth),using artificial bone
7.The following user should be agreed by the professionals before using this device
----- Patients with acute disease
----- Patients with malignant tumor
----- Patients with Infectious disease
----- Pregnancy women
----- Cardiac disease
----- Patients with high fever
----- Being treated or physical abnormalities
8.Please immediately turn off power supply , stop using if following abnormal situation happened
(1)Water and other matter into the host
(2)Host ,power supply line ,accessories line and plug etc. occur the abnormal heating, leakage
(3)The sound to be unusual
(4)Abnormal smell,smoke.
(5)Any accessories damaged
(6)Natural disasters and earthquake,the sudden thunder
9.When the treatment is finished ,please cut off the power supply,be sure to unplug the power plug from the power socket
10.Please check the power supply line,accessories line carefully every time before use,if found damaged,you should stop using and replacing it
11.Transportation and storage conditions:Transport according to the requirements of the order conteact,the transpord process should be to prevent sun and rain; packaged equipment should be stored in relative humidity of not more than 80%,no corrosive gas and ventilated room.
12.The warning mark produce in the specification,its purpose is to enable you to safely and correctly using this dvvice,and to prevent you and others to injury.
Maintenance
1.Appliances and medical equipment close to the machine may be resuting in operational failure due to interference.
2.Prohibie use of the equipment in the following environment
----Hot and humid environment
---- Dusty environment
---Environmental with much smoke or stream
3.If there comes a failure,please shut down the power immediately,and send it to the distributor or manufacturer for maintenance.Do not repair by yourselt.
4.Exclusion of liability
The Company is not responsible for the following circumstances:
(1)If fire,earthquake,war occurred;
(2)The fault of the user,operator error;
(3)Damage caused by using other method(not included in the use manual).
(4)Operate without the manual’s guide.
5.After using the machine for over 40 hours,please take off the dust filter and clean it (If have).
6. Do not make the machine close to the wall,keeping a 30CM space around for cooling.
Safety and Environmental Considerations
Technical note
Hardware structure of the machine parts,injection molded parts,and the majority of electronic components,connectors,meet the requirements of the EU and China RoHS directives,Only a few part as the global technology limitatiobs that may affect product reliability,and not find a substitute for the toxic and hazardous substances,please be assured to use,use under normal conditions will not cause health effets on users.
Micro Fractional Co2 Laser Machine For Removing Intractable Chloasmas / Pigmentation
Specifications:
Laser type | Carbon Dioxide Fractional Laser |
Laser wavelength | 10600nm |
Laser power | Up to 40W (optional) |
Light system | 7 joint arms |
Pulse duration | 100-5000MS |
Facula | Single mode |
Focussed diameter of the beam | 0.25mm |
Focal area | 0.05mm2 |
Output form | Ultra Pulase, fractional |
Scanning Mode | Sequence, random, parallel (switchable) |
Scanning shapes | Triangle/square/rectangle/round/oval/hexagon/linear |
Area of diagram | ≤20mm*20mm |
Interface colourful touch screen | 8.4 inch |
Refrigerating system | Air-cooling, water-cooling |
Input power | AC230V±10%, 50Hz/ AC 110V ± 10% 60Hz |
Work Mode | Intermittent loading |
How it works?
CO2 Fractional Laser System fires a laser beam which is split into numbers of microscopic beams, producing tiny dot or fractional treatment zones within the selected target area only. Therefore, the heat of laser only passes deeply through the fractional damaged area. This allows the skin to heal much faster than if the whole area was treated. During the skin self-resurfacing, a great amount of collagen is produced for skin rejuvenation, eventually the skin will look much healthier and younger.
Is Fractional CO2 laser treatments safe to treat acne scars in darker skin types?
Dr. Schweiger safely treats acne scars in patients with all skin types including Asian, Indian, and African-American skin. An experienced laser surgeon is needed to treat darker skin types safely.
What is the downtime for this laser treatment?
The fractional CO2 laser causes a wound in the skin which means you will have three to four days of downtime when the skin is healing. During that time you have to apply an ointment frequently to your face keep the skin greasy, which makes healing faster.
What are the side effects of Fractional CO2 resurfacing?
The main risks are temporary or long-lasting light or dark spots from treatment. Very rarely scarring can still result. For these reasons it is important to be treated by an experienced laser surgeon.
What type of anesthesia is used during the procedure?
The whole procedure is done under local or topical anesthesia. You are awake and comfortable the entire time. Prior to the procedure, topical numbing cream is applied for 60-90 minutes. In addition, valium is given prior to the procedure to facilitate relaxation. Using these measures there is usually minimal discomfort during the resurfacing procedure.
Applications:
Skin renewing and resurfacing
Wrinkle removal, skin tightening
Acne and acne scar removal
Smooth burnt scars and surgery scars, etc
Remove intractable chloasmas and pigmentation
Sun damage recovery.
Advantages:
1. It will have thermal shock on a small area of skin and retain that portial skin is not affected
2. The fractional laser can remove the stain of the skin to stimulate the hyperplasia of collagen
3. Without effecting to the skin organizations as the thermal diffusion region to avoid any possible heat injury and to promote the healing of skin
4. A few days after collagen hyperplasia of micro-heating area appear micro-callus exfoliation, the effects of treatment maintained over the years
5. Operate easily, pain is minor, non-bleeding, no side effects, short recovery period
6. Shorter treatment time, non-chromatosis and no pigment miss out, no additional consumables
7. Cover area of 20% every treatment, total 4-6 times treatment, interval 3-4 weeks.
Contact Person: Ms. Hu
Tel: 1393380568
Fax: 86-755-3987544
Industrial Grade Mixed refrigerant Retrofited refrigerant for R22
Mixed refrigerant / Retrofited refrigerant for R22 and R502
Mixed Refrigerant R404A (HFC-404A) Recyclable cylinder 400L / 800L / 926L
Economical R134 replacement (HCFC) r22 refrigerant cylinder / chlorodifluoromethane r22
R22 Refillable cylinder Odorless 1000L CHCLF2 R22 Refrigerant Replacement
R22 Replacement Chlorodifluoromethane (HCFC-22) home air conditioner refrigerant gas
R134a Pure gas cooling agent R134a refrigerant 30 lb Air Conditioning and Heat Pumps
Car automotive air conditioning r 134a refrigerant 30 lb, High Purity 99.90%
HFC R134a Auto air conditioning CH2FCF3 R134a Refrigerant 30lbs for commercial, industrial